Can I have two versions of Ranger installed on the same pc?

Can I have two versions of Ranger installed on the same pc?

Yes. The installation of two or more versions of Ranger for different transports on the same PC will not cause any conflicts between the versions.
Please note though that the Ranger installer registers the Ranger control for the transport being installed, and, therefore, only the Ranger version installed last can be used until a different Ranger control is registered.

For example, if Ranger for the CR-180 is installed first and then Ranger for the MVX is installed, the Ranger-based application would work with the MVX scanner but not the CR-180 because Ranger for the CR-180 is no longer registered with Windows. In order for the application to again work with the CR-180, Ranger for the CR-180 must be re-registered using the following steps:

[Windows XP]
  1. Close all Ranger based applications.
  2. Select [Start Menu].
  3. Select [Run].
  4. Type 'regsvr32 [Drive]:\[Full path to Ranger.ocx]\Ranger.ocx'.
  5. Press 'OK'.

[Windows Vista and 7]
  1. Close all Ranger based applications.
  2. Browse to the Windows System32 folder
  3. Locate the cmd.exe file
  4. Right-click on cmd.exe
  5. Select "Run as Administrator"
  6. Type 'regsvr32 [Drive]:\[Full path to Ranger.ocx]\Ranger.ocx'.
  7. Press enter

Please note that the default installation path for the Ranger.ocx file is 'C:\Program Files\Silver Bullet Technology\Ranger\<transport>\API Files\Ranger.ocx'

After pressing 'OK' or hitting enter, above, a prompt will be displayed stating that 'DllRegisterServer in [Entire path and OCX name] succeeded'.

Another method to register the Ranger control for the transport you would like to run is by using the Ranger Control Center tool available on www.sbullet.com.  Please log in and follow the Ranger SDK link.

Ranger v3+ is plug-in based and uses a Ranger core. The Ranger core OCX file is located in the path below.

32 bit OS
      C:\Program Files\Silver Bullet Technology\Ranger\Ranger.ocx
64 bit OS
      C:\Program Files (x86)\Silver Bullet Technology\Ranger\Ranger.ocx

Switching between Ranger can be done per the following:

Switch
Actions
Ranger v2 to v3+
Register the Ranger core mentioned above.
Ranger v3+ to v2
Register the "Ranger.ocx" appropriate for your scanner.
Ranger v3 +to v3+
No action required.

Please keep in mind that Ranger v2 drivers are still actively developed.

Copyright © 2023 Silver Bullet Technology
www.sbullet.com


    • Related Articles

    • How do I resolve an error of "R6030 - CRT not installed" during installation?

      Make sure you're installing Ranger with Administrator permissions. If this problem continues then this is most likely a result of corrupt MFC v7 Redistributables. To resolve this problem, unzip and copy the attached files into the system directory. ...
    • What are Ranger's minimum PC system requirements?

      What are Ranger's minimum PC system requirements? Ranger has the same system requirements as the check scanner it is used with. The minimum system requirements for a particular check scanner are available from the scanner manufacturer. Operating ...
    • Does my older Canon CR-180 support PC sorting?

      Newer versions of the Canon CR-180 allow the application to make pocket decisions on a per-item basis using Ranger's SetTargetLogicalPocket() call. Although visually the older and newer models appear very similar, there are significant mechanical ...
    • How do I unlock Ranger again on the same PC, or another PC?

      Ranger v4.9 and older Ranger uses a "node-locked" licensing model. Once a Ranger license is unlocked on a computer, it is bound to that workstation. Occasionally, a workstation may need to be replaced or the hardware signature may change due to ...
    • Why is Ranger not generating any logs (Windows Vista)?

      If you have multiple versions of Ranger installed on this pc, you might have complications from co-installing a Vista enhanced Ranger with a non-Vista enhanced Ranger. A Vista-compatible version of the Ranger Control Center is required to view the ...