How can I reduce the number of false double-feeds on a Digital Check TS-Series Scanner?
The Digital Check TS-Series scanners have an option called
"DoubleFeedNoStop" which may significantly reduce false double-feed
exceptions.
When this option is enabled, the scanner will not
stop immediately when a the feeder's double-feed detector senses a
suspect item(s). Instead the scanner will examine the image and MICR
data to determine if it is a real double feed or a false positive.
If
the scanner determines it to be a real double feed, feeding will stop
when the item reaches the pocket and a Ranger double-feed exception will
then be fired.
This option can be set by editing the scanner's driver options file:
- DCCOptions.ini - In old versions of Ranger
- DigitalCheck-TSSeries.ini - In newer versions of Ranger
- [Misc]
DoubleFeedNoStopEnabled = true
To set this option in your program, and any time after starting up Ranger and before enabling Ranger options, call:
- Ranger.SetDriverOption("DoubleFeedNoStopEnabled", "true")
Note: This option is only active when double-feed detection is enabled in Ranger's generic options.
Related Articles
How to capture OEM logs for TS -Series scanners
To enable logging: Open the DigitalCheck-TSSeries.ini file, which you can find at this location: C:\ProgramData\Silver Bullet Technology\Ranger\Scanner Plug-ins\DigitalCheck-TSSeries\DigitalCheck-TSSeries.ini In the [Misc] section, set DelayTS200=2 ...
Windows Digital Signature verification won't allow my scanner to run
We have seen some instances of various scanners unable to connect with their internal device drive due to a problem with Digital Signatures: "Windows cannot verify the digital signature for the drivers required for this device. A recent hardware or ...
Switch driver options INI files when using different check scanner models?
Question: Can I switch Ranger driver options files based on the scanner model? I would like to use one file when connected to a Digital Check TS 230 or TS 240 scanner, and a different driver options file when connected to a TS 4120. Answer: "Ranger ...
How can I contact Digital Check tech support?
For Digital Check technical support, use the contact details below. DCC technical support: Phone: 847-446-2285 Email: support@digitalcheck.com Ranger® - The universal check scanner interface Copyright © 2023 Silver Bullet Technology www.sbullet.com
Can check scanner OCR read check amounts, dates, signatures, etc.?
The OCR capability that comes with check scanners cannot read check amounts, dates, signatures and so on. There are vendors that offer software that can read this type of information from checks. Some of the companies that offer popular check reading ...